Master Worksite Facility

Measurements

  • width 3,300 mm
  • length 7,200 mm
  • external height 2,820 mm
  • internal height 2,400 mm

Platform

  • interchangeable platform
  • IPE-160 steel profile
  • painted black

Floor element

  • plastic mat 1.5 mm
  • spruce plywood 12 mm
  • wooden frame 45*95 T24 k600
  • polyurethane 95 mm
  • coated low-profile sheet metal 3/0.5
  • U= 0.342 W/m2K

Ceiling element

  • profile sheet metal W-45A, zinc-coated
  • hardboard 3.2 mm
  • wooden frame 45*95 T24 k600
  • polyurethane 95 mm
  • MDF board 6 mm, painted white
  • U= 0.347 W/m2K

Outside walls

  • low-profile sheet metal 3/0.5, coated RR21 (light grey)
  • wooden frame 45*60 k1220
  • polyurethane 60 mm
  • white lacquered plywood 6.5 mm
  • U= 0.477 W/m2K
  • there are fastening boards for the fastening of lockers on the outside walls of the C08, A, B and D facilities

Outside door

  • steel sheet structured 9/21, zinc-coated/grey
  • security lock brackets
  • anti-theft pegs
  • door pump
  • lock case Abloy 4190
  • lock cylinder Abloy CY001, not serialized

Windows 15×12 TL

  • PVC plastic, white
  • 2-k, U= 1.4 W/m2K
  • air vent
  • inside cover strip PVC, white
  • blinds and inside window bars, white
  • air vent

Outside battens

  • corner battens, steel profile 2.0 mm, zinc-coated
  • gutter, zinc-coated steel, 1.5 mm

Hoist rings

  • zinc-coated

Dividing walls

  • white lacquered plywood 6.5 mm
  • wooden frame 48*55 k 600
  • mineral wool 50 mm
  • white lacquered plywood 6.5 mm

Shower facility

  • floor elevation + raising the mat on the wall, 100 mm
  • wall board plywood 6.5 mm, plastic mat on the surface with welded seams

Connecting doors

  • flush door 9/21, white
  • cover strips 12*42, brown
  • button, keyplate
  • lock

Inside battens

  • cladding batten 16.5*36, brown

Electric room

  • main switch and safety devices
  • electricity supply with 5*32 A electrical plug
  • electricity supply linkage with 5*32 A outlet
  • metal structures and water pipelines are grounded

Heating

  • combination heaters, solid thermostats

Lighting

  • fluorescent lights in the ceiling

Outlets

  • 2-part, grounded outlets

Cabling and furniture

  • as surface installations
  • cable trays at the ends in a C01 sales facility, outlets installed in the cable tray

HVAC

  • ventilation in dry spaces with poppet valves
  • IV channel blower in social facilities
  • water and waste water disposal out from the end wall

Additional equipment to be ordered separately (unless included in standard delivery)

  • lockers with front benches
  • kitchen furniture
  • tables and chairs
  • drying cabinets (for D facilities)
  • connection fittings for sliced seams
  • cable trays under gable windows
  • notice boards